Steam rankine cycle technology

WHR system SRC-based integrated in a full gas treatment system (DeSOx +ESP+SCR DeNOx)

Figure 4 view of WHR system SRC-based in Belarus.

Basic design data

BOILER GAS FLOW Nm3/h 110.000
PRODUCED STEAM t/h 15,3
STEAM TEMPERATURE AND PRESSURE °C – bar 350 – 36
TURBOGENERATOR CAPACITY MV 2,9
TURBINE RATED OUTLET SPEED RPM 1500
MAX WHR THERMAL POWER kWt 11.322

Scope: WHR system SRC-based integrated in a full gas treatment system (DeSOx +ESP+SCR DeNOx)
Country: Belarus
Technological choice: Steam Rankine Cycle
Turbogenerator capacity: 2,9 MW
Fully Integrated operation with the gas treatment system.