Organic Rankine Cycle Technology

WHR ORC-based design with dual loop configuration to produce clean energy

FULL EPC Turn-key project: overall management from Engineering to Commissioning & Start-up of the Waste Heat Recovery System

Figure 1 view of heat recovery boiler & air coolers in Sonmez cement factory, Turkey

Basic design data

BOILER GAS FLOW Nm3/h 225.608 / 345.750
TURBOGENERATOR CAPACITY MV 8,3
TURBINE RATED SPEED RPM 3.000
MAX WHR THERMAL POWER kW 29.809

Scope: Full WHR-ORC (Heat Recovery Boiler + ORC System)
Country: Turkey
Application: Pre-heater (PH) + clinker cooler (AQC)
FULL EPC Turn-key project: overall management from Engineering to Commissioning & Start-up
Technological choice: Organc Rankine Cycle.
Dual-loop configuration with No.2 recovery boilers on clinker cooler air (AQC) and kiln-preheater gas (PH);
One single stream of oil to ORC, with intermediate heat exchangers between thermal Oil and Organic fluid; No.1 ORC with Cyclopentane.